Appendix B
Serial Port Pin Outs
It is possible to connect a variety of telemetry cameras to the unit, use the following tables as a
guide. Supported protocols are listed in Appendix F - Unit Specication.
1
5
6 9
RS232 Connectivity
Pin Description
2 Receive Data
3 Transmit Data
5 Ground
RS485 Connectivity (2 wire)
Pin Description
1 RS485 + (A)
9 RS485 - (B)
5 Shield (GND)
Note: A cable can be manufactured that connects pins 2, 3 and 5 to an RS232 device and pins
1,9 and 5 to an RS485 device. This allows two devices to be assigned to the same D type
connector.
Shared Cable wiring
RS232 Device RS485 Device
DVR Dtype
6
1 5
96
1 5
9
6
1 5
9